Leave Your Message
High-Low Temperature Linear Module from China Suppliers | Stepper Motors for Cryogenic and Radiation Applications
Hot Products
Products Categories
Featured Products

High-Low Temperature Linear Module from China Suppliers | Stepper Motors for Cryogenic and Radiation Applications

,
,
    ,
  • High-performance stepper motors designed for vacuum, cryogenic, high temperature, and radiation applications, perfect for industrial use in China.
  • ,
  • Vacuum Performance: Operational capability up to 10-7Pa, making them ideal for advanced scientific environments.
  • ,
  • Operating Temperature Range: Reliable performance from -196°C to 200°C, suitable for extreme conditions.
  • ,
  • Radiation Resistance: Designed to withstand radiation exposure of up to 106Gy, ensuring durability in harsh settings.
  • ,
  • Base Width Options: Available in a variety of sizes including 30/40/60/80/135/170mm to meet diverse application needs.
  • ,
  • Maximum Load Capacity: Supports up to 150Kg horizontally and 100Kg vertically, making them versatile for various operational scenarios.
  • ,
  • Repeatability: Achieves high precision with a repeatability of ±0.01mm, critical for intricate applications.
  • ,
,

As a leading China supplier and factory of stepper motors, we ensure quality and reliability for all your engineering requirements.

,
,

    Ordering Information

    KLS
    1 Product series

    KLS series linear motion stage

    2 Base width(mm)

    30 = 30mm

    40 = 40mm

    60 = 60mm

    80 = 80mm

    140 = 135mm

    170 = 170mm

    3 Stroke length(mm)

    50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600, 650, 700, 750, 800, 850, 900, 950, 1000, 1050, 1100, 1150, 1200, 1250, 1300, 1350, 1400, 1450, 1500

    Please refer to the specification tables for the available stroke length.

    4 Screw lead(mm)

    2, 4, 5, 10, 16, 20mm

    Please refer to the specification tables for the available screw lead.

    5 Motor mounting

    ISC: in-line (with coupling)

    PR: parallel on right side (with high precision gear, ratio 1:1)

    PL: parallel on left side (with high precision gear, ratio 1:1)

    PB: parallel below the linear motion stage (with high precision gear, ratio 1:1)

    Motor Mounting Options
    6 Environmental temperature ratings
    Environmental temperature rating code Temperature range (℃) Vacuum class (Pa, optional) Radiation resistance (Gy, optional)
    RHT -20~+200 10-3 106
    SHT -20~+200 10-3/10-5/10-7 -
    HT -20~+150 10-3/10-5/10-7 -
    NTL1 -40~+85 10-3/10-5 -
    NTL2 -40~+100 - -
    NTL3 -65~+125 10-3 -
    NTL4 -80~+40 10-3 -
    NTL5 -55~+150 - -
    7 Vacuum class

    Blank: Non-vacuum

    V3: Low pressure or vacuum to 10-3Pa

    V5: Vacuum to 10-5Pa

    V7: Vacuum to 10-7Pa

    8 Radiation resistance

    Blank: No radiation resistance

    RH: Radiation resistance (total dose 106Gy)

    9 Designator of mounted motor

    e.g.

    KH42: KH series 42mm stepper motor

    KVM57: KVM series 57mm stepper motor

    KECM400: KECM series 400W servo motor

    KSSM750: KSSM series 750W servo motor

    PB60L2: PB60 2-stage reducer (please specify the reducer stage, e.g. L1 or L2)

    Description

    Core Perspective: Balancing "low-temperature sample viability" with "contamination prevention" in automated workflows

    The core dilemma of automated genetic sampling equipment is that sample viability demands a consistently cryogenic environment (-196°C liquid nitrogen), while mechanical transmission systems conventionally freeze and fail at such temperatures due to lubricant solidification. The KLS Series High-Low Temperature Linear Module resolves this contradiction. This high-low temperature linear module is specifically optimized for low-temperature automation in the biomedical industry, focusing on startup torque characteristics. When the ambient temperature plummets to min -196°C, standard motors suffer step-loss as the coercivity of their magnets degrades. In contrast, this high-low temperature linear module employs samarium-cobalt (SmCo) cryogenic-grade magnets, ensuring rated torque output even at liquid nitrogen temperatures.

    During the lysis step of nucleic acid extraction, the equipment may rapidly heat to max +200°C to inactivate proteases. The housing of this high-low temperature linear module undergoes special heat treatment to withstand repeated thermal stress without distortion. For sterile sampling requirements, the surface of this high-low temperature linear module is coated with a material resistant to ethanol and vaporized hydrogen peroxide (VHP), with a seamless, crevice-free design facilitating cleaning validation. Operating under a vacuum degree of 10^-7Pa, this high-low temperature linear module suits next-generation fully enclosed sterile sampling systems, effectively preventing cross-contamination. Remarkably, the KLS Series High-Low Temperature Linear Module withstands radiation intensity of 10^6Gy, meaning it will not become a source of radiation-induced degradation when used on production lines for radiation-sterilized vaccines.

    Regarding mechanical selection, the miniature body width of 30mm high-low temperature linear module can be directly embedded into the sampling platform of a microfluidic chip. Its repeatability of ±0.01mm ensures precise alignment between the pipette tip and the microwell. Meanwhile, the wide-body 135mm width version, with a maximum vertical load capacity of 100kg, can carry an entire deep-well plate stacker. In an automated library preparation workstation for next-generation sequencing (NGS), multiple high-low temperature linear modules work in concert, performing all actions from magnetic bead mixing and washing to elution. The key here is that after repeated operation at min -196°C, the straightness of the high-low temperature linear module does not degrade due to microscopic ice crystal formation on rail surfaces. The KLS Series High-Low Temperature Linear Module incorporates precision scrapers and anti-condensation airflow designs, maintaining ±0.01mm repeatability even under extreme humidity swings. For high-throughput qPCR systems used in pathogen detection, this high-low temperature linear module rapidly shuttles sample plates between different temperature zones, compressing overall reaction time. In summary, the KLS Series High-Low Temperature Linear Module is not merely a transmission component; it is a core enabler of sample integrity and high-throughput automation in biomedicine.

    KLS Application
    Frequently Asked Questions (FAQ)
    What is the operating temperature range of the KLS Series linear module?
    The KLS Series is engineered to withstand extreme thermal conditions, operating from cryogenic liquid nitrogen temperatures as low as -196°C up to high temperatures of +200°C.
    How does the module prevent step-loss at extremely low temperatures?
    Instead of standard magnets which degrade in coercivity at low temperatures, the KLS Series utilizes samarium-cobalt (SmCo) cryogenic-grade magnets to guarantee rated torque output even in liquid nitrogen environments.
    Is the KLS Series suitable for sterile and vacuum environments?
    Yes, it features a seamless, crevice-free design with a surface coating resistant to ethanol and VHP. It can operate in high vacuum environments up to 10-7Pa, preventing contamination.
    Can this module be used in radiation-sterilized environments?
    Yes, the KLS Series is designed to withstand radiation intensities up to 106Gy, preventing radiation-induced degradation during automated vaccine production or sterilization processes.
    What sizing options are available for different load capacities?
    It ranges from a miniature 30mm base width suitable for microfluidic chips up to a wide-body 135mm version capable of handling vertical loads of up to 100kg.
    How does the module maintain its ±0.01mm repeatability under extreme conditions?
    The module features high-integrity structural components, precision scrapers, and anti-condensation airflow designs that prevent microscopic ice crystal formation on rail surfaces during deep temperature swings.

    Leave Your Message